Dispatch towels are approved for use in multiple healthcare locations, including hospitals, laboratories, physician and dental offices and nursing homes.
Ideal for stainless steel equipment at point-of-care: IV poles, blood glucose monitors and stethoscopes.
Suitable for general surfaces such as counters, chairs, exam tables, telephones, light switches and sealed computer keyboards.

REMOVE gross soil if visible.†

WIPE surface with towel until completely wet. Gloves should be worn.

To DISINFECT, allow surface to remain wet for 1 minute. To kill TB, allow 2 minutes contact at room temperature. To kill C. difficile spores, allow 5 minutes contact.

WIPE with a clean, damp cloth. Allow to air dry. Discard used towel.
This product may be used on stainless steel, glazed ceramic tile, hard plastics, nonporous vinyl, painted surfaces, Plexiglas, laminated plastic countertops, fiberglass (sealed) surfaces, glazed porcelain and glass.
CAUTION: Causes moderate eye irritation. Avoid contact with eyes or clothing. Wash thoroughly with soap and water after handling.
Do not use this product with ammonia or acids such as vinegar, rust removers or toilet bowl cleaners. Not intended for use on fabrics.
Use by expiration date.
†This is a one-step product. Precleaning is required for Clostridium difficile applications and if gross soil (blood, vomit, fecal matter or other soil) is visible.

REMOVE gross soil if visible. For C. difficile spores, always clean surface prior to disinfecting†

POUR directly onto hard, nonporous surface or a clean, dry cloth or microfiber cloth. Wipe surface with cloth until completely wet. Gloves should be worn.

To DISINFECT, let stand for 1 MINUTE. To kill TB, allow 30 seconds contact at room temperature. To kill C. difficile spores, allow 5 minutes contact. WIPE with a clean, damp cloth. Allow to air dry.

Fold clean cloth in half.

Fold cloth in half again. Saturate cloth with DISPATCH®.

Use side 1. Turn cloth over to use side 2.

Unfold cloth once and fold over to use sides 3 and 4.

Unfold cloth completely, then fold in half to expose sides 5 and 6 on the outside.

Use side 5. Turn cloth over to use side 6.

Unfold cloth once and fold over to use sides 7 and 8. Discard soiled cloth in laundry.
* Rubbermaid HYGEN™ Product Use Manual: “How to Use 8-Sided Fold with Microfiber Cloths.” Use product as directed.